Customization: | Available |
---|---|
Certification: | CCC, ISO |
Power Supply: | AC220V |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
RQ RQM series Three, the main technical parameters * Input signal: (1) Analog signal A.4-20mA.DC input impedance 250Q b.0-10mA.DC input impedance 250Q (2) Switching signal *Output signal (1) Valve position feedback signal: 4-20mA.DC load impedance <750Q *The output shaft torque, speed, stroke, and time are shown in Table 1, Table 2, Table 3, Table 4, Table 5, table 6, and Table 7. *The power consumption of intelligent electric devices is shown in Table 1 and Table 2. *Basic error: (1) RQ, RQM multi-turn intelligent electric device <±1 % (2) Standard angle-stroke electric device, adjustable angle-stroke intelligent electric device < ±1 % (3) RQML straight stroke intelligent electric device stroke = 25mm < ± 1% *Dead zone 0.1~9.9% adjustable, the default setting is <0.5% *The setting range of the midway limit opening limit is 40%~100% The setting range of the off limit is 0%~60% *Clearance: (1) RQM multi-turn adjustable intelligent electric device <1 (2) RQ multi-turn standard intelligent electric device <1° (3) RQML straight stroke intelligent electric device <1mm. (4) Adjustable angle stroke intelligent electric device <1° (5) Standard type angle stroke intelligent electric device <1° *Disable running time, adjustable from 0 to 99 seconds *Power supply: three-phase three-wire system voltage: 220V, 380V, 415V, 440V, 460V. Frequency conversion voltage 220V, 380V Frequency: 50/60Hz *Shell protection level: IP68 *Explosion-proof level: (1) Remote control intrinsically safe type ib II BT4 (2) The intelligent electric device is explosion-proof type d II BT4, d II CT4 *Output contact capacity: 220V.AC , 5A; 30V.DC, 5A *Operating environmental conditions (1) Ambient temperature: -25~+70°C (explosion-proof type: -20~+60°C) (2) Relative humidity: 5%~98%; (3) Atmospheric pressure: 86~106kPa; (4) Air medium: there is no corrosive gas in the surrounding air. * Anti-interference index: A. External magnetic field 400A/m, 50Hz B. Common mode interference 250V, 50Hz C. AC signal with an effective value of 1V for string-mode interference The frequency is 50Hz, the phase is 0~360° D. Electrostatic discharge: 4kV E. Electric fast instantaneous burst: 1000V at the power supply terminal; 500V at the signal input terminal. F. Radio frequency interference: frequency 80~1000MHz, test site strength 3V/m, distance 1m G. Surge interference: 1kV 02